Publicações

Referências utilizadas nos textos do site:

[1] ANVISA, “Resolução Da Diretoria Colegiada – Rdc N° 34, De 11 De Junho De 2014,” Diário Of. da União, vol. 113, pp. 1–123, 2014.

[2] S. Kleinman and A. Stassinopoulos, “Transfusion complications,” vol. 58, no. November, 2018, doi: 10.1111/trf.14930.

[3] K. Janatpour, L. Denning, K. Nelson, B. Betlach, M. MacKenzie, and P. Holland, “Comparison of X-ray vs. gamma irradiation of CPDA-1 red cells,” Vox Sang., 2005, doi: 10.1111/j.1423-0410.2005.00699.x.

[4] B. H. Greenbaum, “Transfusion-associated graft-versus-host disease: Historical perspectives, incidence, and current use of irradiated blood products,” J. Clin. Oncol., vol. 9, no. 10, pp. 1889–1902, 1991, doi: 10.1200/JCO.1991.9.10.1889.

[5] J. C. Borges, D. T. Covas, M. D. Orellana, and F. R. Morais, “Blood components,” vol. 46, no. January, pp. 34–40, 2006, doi: 10.1111/j.1537-2995.2006.00669.x.

[6] N. Tufft, “Case reports THIRD PARTY MEDIATED GRAFT REJECTION DESPITE IRRADIATION OF BLOOD PRODUCTS,” Br. J. Haematol., vol. 80, pp. 251–262, 1992, doi: 10.1177/175114371401500314.

[7] L. S. Del Lama et al., “Prevention of Transfusion-Associated Graft-versus-Host Disease by Irradiation: Technical Aspect of a New Ferrous Sulphate Dosimetric System,” PLoS One, vol. 8, no. 6, 2013, doi: 10.1371/journal.pone.0065334.

[8] D. E. Bedolla et al., “Effects of soft X-ray radiation damage on paraffin-embedded rat tissues supported on ultralene: a chemical perspective,” J. Synchrotron Radiat., vol. 25, no. 3, 2018, doi: 10.1107/S1600577518003235.

[9] L. N. Button, W. C. Dewolf, P. E. Newburger, A. N. D. S. V Kevy, H. Medical, and F. Cancer, “The Effects of Irradiation on Blood Components,” vol. 21, no. 4, 1977.

[10] J. Treleaven et al., “Guidelines on the use of irradiated blood components prepared by the British Committee for Standards in Haematology blood transfusion task force,” Br. J. Haematol., vol. 152, no. 1, pp. 35–51, 2011, doi: 10.1111/j.1365-2141.2010.08444.x.

[11] T. Fearon, V. R. Criss, and N. L. C. Luban, “Blood irradiator dosimetry with BANG polymer gels,” Transfus. Complicat., vol. 45, 2005, doi: 10.1111/j.1537-2995.2005.00573.x.

[12] O. Moussous, S. Khoudri, and M. Benguerba, “Characterization of a Fricke dosimeter at high energy photon and electron beams used in radiotherapy,” Australas. Phys. Eng. Sci. Med., vol. 34, no. 4, pp. 523–528, 2011, doi: 10.1007/s13246-011-0093-1.

[13] P. M. D. E. Oliveira, “Avaliação de dose nos sistemas de irradiação de bolsas de sangue para esterilização,” Instituto de pesquisas energéticas e nucleares, 2014.

[14] C. E. Dealmeida et al., “A feasibility study of Fricke dosimetry as an absorbed dose to water standard for 192Ir HDR sources,” PLoS One, vol. 9, no. 12, pp. 1–13, 2014, doi: 10.1371/journal.pone.0115155.

[15] C. Salata et al., “Validating Fricke dosimetry for the measurement of absorbed dose to water for HDR 192 Ir brachytherapy: a comparison between primary standards of the LCR, Brazil, and the NRC, Canada,” Phys. Med. Biol., vol. 63, no. 8, p. 085004, Apr. 2018, doi: 10.1088/1361-6560/aab2b8.

[16] A. Mantuano, G. J. De Amorim, M. G. David, P. H. G. Rosado, and C. Salata, “Linearity and reproducibility response of Fricke dosimetry for low energy X-Ray beam,” pp. 4–7.

[17] L. Franco, S. Gavazzi, and C. E. de Almeida, “Determination of the G value for HDR 192Ir sources using ionometric measurements,” in International Symposium on Standards, Applications and Quality Assurance in Medical Radiation Dosimetry (IDOS)., 2011.

[18] A. Mantuano, C. Salata, M. G. David, C. L. Mota, G. J. De Amorim, and L. A. G. Magalhães, “Fantoma para Irradiadores de Sangue,” BR 10 2018 073239 0, 2018.

Publicações e patentes:

Artigos submetidos

  • Andrea Mantuano, Camila Salata, Carla Lemos Mota, Arissa Pickler, Leonardo de Castro Pacífico, Luís Alexandre Gonçalves Magalhães, and Carlos Eduardo de Almeida; “Technical Note: Fricke dosimetry for blood irradiators”, Medical Physics, in review, 2020.
  • Mariano G. David, Camila Salata, Carlos E. de Almeida; “Determination of the factors used in Fricke dosimetry for HDR using the Monte Carlo method”, Revista Brasileira de Física Médica, 2020.

Artigos em progresso

  • Andrea Mantuano, Carla Lemos Mota, Camila Salata, Arissa Pickler, Luis Alexandre Gonçalves Magalhães, and Carlos Eduardo de Almeida; “A Feasibility study of a postal dosimetry system using Fricke dosimeter”, 2020.
  • Arissa Pickler, Andrea Mantuano, Camila Salata, Carla Lemos Mota, Mariano G. David, Glorimar J. de Amorim e Carlos E. DeAlmeida; “Effects of chemical reactions between Fricke solution and PMMA vessel”, 2020.
  • Paulo Henrique Rosado, Camila Salata, Mariano Gazineu David, Andrea Mantuano, Arissa Pickler, Carla Lemos Motta e Carlos E. de Almeida; “Determination of the Absorbed Dose to Water in Medium X-rays Energy Beams Using Fricke Dosimetry”, 2020.
  • Carlos Eduardo DeAlmeida, Camila Salata; “Absorbed Dose to Water Standard for Ir-192 HDR Sources using Fricke Dosimetry”, 2020.

CITAÇÕES

ICRU Report 90. Key Data for Ionizing-Radiation Dosimetry: Measurement Standards and Applications. 2014. Cita: Salata, C., David, M., de Almeida, C., El Gamal, I., Cojocaru, C., Mainegra-Hing, E., and McEwen, M. (2014). “Comparison of absorbed dose to water standards for HDR Ir-192 brachytherapy between the LCR, Brazil, and NRC, Canada,” Med. Phys. 41, 388–388.

PATENTES E REGISTROS

Patentes

  1. David, MG., SALATA, C, de ALMEIDA, C. E.
  2. DISPOSITIVO DE PADRONIZAÇÃO PRIMÁRIA DE FONTES 192Ir EM BRAQUITERAPIA, 2014. Categoria: Produto. Instituição onde foi depositada: INPI - Instituto Nacional da Propriedade Industrial. País: Brasil. Natureza: Patente de Invenção. Número do registro: BR1020140090070. Data de depósito: 14/04/2014. Data de concessão: 14/04/2014. Depositante/Titular: Mariano Gazineu David, Camila Salata, Carlos Eduardo de Almeida. Depositante/Titular: Universidade do Estado do Rio de Janeiro. Resumo: Os autores desenvolveram um dispositivo adequado para a padronização primária de fontes de 192Ir, em braquiterapia de alta taxa de dose (HDR-BT), usando a dosimetria Fricke. O dispositivo criado pelos autores consiste em um recipiente, feito artesanalmente em polimetilmetacrilato (PMMA), com um design adequado para que a solução Fricke seja colocada, assim como a fonte de 192Ir, conforme mostra a figura 1. A solução Fricke deve ser irradiada uniformemente, por isso o design cilíndrico do dispositivo. Esta solução é colocada dentro do anel através de uma das entradas superiores. Os autores projetaram duas entradas superiores para que a solução Fricke fosse inserida no seu compartimento através de uma entrada, e o ar saísse através da outra entrada, facilitando este processo que é repetido várias vezes durante todo o procedimento. O cateter contendo a fonte de 192Ir é posicionado de forma que a fonte esteja sempre no centro do volume do frasco. O dispositivo é então submerso em água, dentro de um fantoma específico, e por esta razão seu design foi planejado contendo orifícios em seu corpo para facilitar a submersão em água.

  3. Mantuano, A., David, MG., SALATA, C, Magalhães LAG., Mota CL., Amorim, GJ.
  4. FANTOMA PARA IRRADIADORES DE SANGUE, 2018. Categoria: Produto. Instituição onde foi depositada: INPI - Instituto Nacional da Propriedade Industrial. País: Brasil. Natureza: Patente de Invenção. Número do registro: BR 10 2018 073239 0. Data de depósito: 12/11/2018. Data de concessão: aguardando. Depositante/Titular: Mantuano, A. Depositante/Titular: Universidade do Estado do Rio de Janeiro. Resumo: A presente invenção refere-se ao campo de equipamentos para irradiadores de sangue. Mais especificamente, a presente invenção se refere a um fantoma exclusivo para irradiadores de sangue utilizando a dosimetria Fricke. A presente invenção viabiliza a realização da dosimetria com aumento da acurácia, precisão e reprodutibilidade e diminuição das incertezas envolvidas. Além de possibilitar a verificação da distribuição de dose em todo o volume do canister de irradiação.